Known issues for MiNiFi C++ agent
Summary of known issues for this release.
Known issues in this release include:
-
EFM fails to parse the agent manifest if the
nifi.c2.agent.heartbeat.period
is specified using the "time period" format (for example: "30 sec"). The result is missing metadata and manifest updates, which significantly diminish the management capabilities with EFM.Workaround: If you use MiNiFi with EFM, change the
nifi.c2.agent.heartbeat.period
property to an integer in milliseconds. For example use 30000 for 30 seconds, or 5000 for 5 seconds. - If a C2 flow update is used to publish a non-empty flow, and it is followed by a C2 property
update with agent restart, without a process/service restart between the flow update and
the property update, then the MiNiFi process crashes. If used with the windows service
manager or kubernetes, then those service managers automatically restart the agent after a
crash. State is persisted as usual, so no data is lost, unless volatile repositories are
in use.Workaround: None